Direct free cooling
A method for air conditioning, which is used in data centers has long been successful, is the direct free cooling. This technology produces cold air not mechanically, b use of electricity, but rather uses the coolness of the outside air. If costs for producing of cold can be omitted, you can save significant energy costs (up 85%) in the operation of a data center.
In order not to harm the sensitive servers, while the outside air is only processed and purified before it is discharged into the datacenter. Thus, the limits are adhered to with respect to humidity, temperature and air quality.
Although these Air conditioning option is already proven and been shown cost effective, it has not yet established itself on a broad front. We, innovIT AG, seek to use this technology wherever the conditions for this technology are fit. Not only because it is economically worthwhile, but also because it in contributing to environmental protection.
In order not to harm the sensitive servers, while the outside air is only processed and purified before it is discharged into the datacenter. Thus, the limits are adhered to with respect to humidity, temperature and air quality.
Although these Air conditioning option is already proven and been shown cost effective, it has not yet established itself on a broad front. We, innovIT AG, seek to use this technology wherever the conditions for this technology are fit. Not only because it is economically worthwhile, but also because it in contributing to environmental protection.
The outside air is in Germany about 90% a year cool enough to be used for data center air conditioning, the remaining 10% of the time the cold must be completely or partially produced mechanically. With this double configuration with refrigeration equipment, the investment costs for such a solution are initially higher than that of a conventional cooling, but this overspending is usually amortized by the cost savings very quickly usually within operation in 1-2 years.
Due to the low energy consumption, the direct free air cooling equipment can be operated significantly longer by the UPS during a power failure.
Due to the low energy consumption, the direct free air cooling equipment can be operated significantly longer by the UPS during a power failure.
Direct free cooling can be used in each data center, from small IT-safes to large data center rooms. It is important to pre-examine the conditions for thoroughly whether a trouble-free and safe use of this technology is possible.
We are happy to help.